specifically designed and manufactured for the unique integration of data servers.
Edge Data
Powering Edge Computing with Secure, Scalable Infrastructure
Your data can’t afford to lag – not even for a millisecond. When low-latency matters, your edge infrastructure must be reliable, fast to deploy, and built to last. Any weak link – whether in power, cooling, or security – puts performance at risk.
That’s why Thermo Bond’s fully integrated, environment-controlled edge data centers arrive ready to deploy, with pre-installed power, cooling, and security systems designed to handle the demands of AI workloads, autonomous vehicle data, and cloud applications. Purpose-built for resilience and efficiency, these buildings ensure that your edge network stays online, secure, and running at full capacity – wherever you need it.




Thermo Bond's Modular Data Center Solutions
Built to your specifications, Thermo Bond offers lightweight concrete modular building solutions. Our data center options include the following features:
Lightweight Building – Aggregate Panel Exteriors
- Single building sizes from 6′ W to 14’W up to 50’L standard. Larger custom sizes to 14′ X 72′
- Multi-building modules joined together for larger floor spaces
- Minimum floor loading of 200 PSF
- Minimum roof loading of 100 PSF
- Minimum roof impact resistance of 220 foot-pounds
- Minimum wall wind loading of 120 MPH. Higher values available
- Steel skid assembly
- R-values to meet state and local requirements
- Fully integrated with all support equipment, HVAC, electrical, controls and security
Pre-Cast Solid Concrete Buildings
- Typically range in size from 6′ x 8′ to 12′ x 40′ single building, up to 24′ X 40′ and 36′ X 40′ sizes in multi-modular buildings
- 5000 PSI lightweight solid concrete with billet steel reinforcing bars
- Meets ASTM A-615 grade 60 specifications and ACI-318 building code
- 2 hour fire rating
- Bullet resistant up to and including 30-06 caliber rifle– UL-752 level 4
- Floor loading of 200 PSF reinforced concrete with step joint design
- Roof loading of 150 PSF reinforced concrete with 1/4″ per foot roof slope to eaves
- Wind loading up to 200 MPH steel reinforced concrete walls
- R-values and fire ratings to meet state and local requirements
- Fully integrated with all support equipment, HVAC, electrical, controls and security
Micro Data Center (MDC)
- Sizes of single buildings from 8′ X 8′ to 12′ x 50′ – 8KW – 16KW – 32KW – 48KW – 96KW – 112KW
- Lightweight or concrete construction (to 50′ lengths)
- State code approvals
- HVAC, security, monitoring, backup power solutions
- Fully integrated – ready to operate
- R-values and fire ratings to meet state and local requirements
- Building management with remote capabilities
- Thermal management features including hot/cold containment
- N+1 option
For more information on Thermo Bond Buildings, please call 800-356-2686 or email us at info@thermobond.com. We look forward to providing a solution for your building needs.