EVU-200Edge Vault Unit
One precast concrete vault with power, cooling and fire protection built in. Best for edge, telecom and utility sites.
- Buildings
- 1
- IT load
- 200 kW
- Racks
- 8 at 25 kW
Critical infrastructure built to be a good neighbor.
A closed glycol-and-water loop, filled at commissioning.†
Air-cooled by design. Heat goes to air, not to a municipal system or an aquifer.
~As quiet as a commercial refrigerator. Chillers are packaged with sound insulation.†
A full EVC-2500. Plan 1.3–1.6 acres of parcel.
† Reference-design values. Water use and sound at the property line are confirmed for each project during site review.

One precast concrete vault with power, cooling and fire protection built in. Best for edge, telecom and utility sites.

Two buildings: one for servers, one for power. 575 kW for high-density GPU racks.

Nine vaults on one fenced acre, 2.5 MW. Regional capacity that grows as you sign tenants.

Find your land on the map, tell us the IT load you need and lay out Edge Vaults to scale, with generators, chillers and drives. Save it and send it to us for a factory quote.
“Traditional compute facilities are built on site, one project at a time. Edge Vaults are designed once, cast and integrated in our plants, and delivered ready to set. Your schedule depends on site and power, not on starting a new building from scratch.”
One large site puts every megawatt on one utility hookup, one community and one storm path. Distributed Edge places capacity across many smaller sites near power with room, so a single event touches a fraction of the network.
Illustrative comparison. Site locations and tornado path are examples, not real projects or a forecast. Each EVC-2500 campus needs a 1.3–1.6 acre parcel for stormwater, staging and the utility easement. Actual siting depends on available utility capacity.
Parcels by substations, along rights-of-way and on hard-to-use ground.
Many small power draws spread across the grid, instead of one huge draw on a single substation.
We build where power is already available, instead of waiting in line for a new utility connection.
Lease income for landowners and new property tax base for counties.
| Compare | EVU-200 | EVN-575 | EVC-2500 |
|---|---|---|---|
| Buildings | 1 | 2 | 9 |
| IT load | 200 kW | 575 kW | 2.50 MW |
| Cooling | In-row, hot-aisle containment, chiller | Air-cooled at the rack | Air-cooled at the rack, sealed glycol loop |
| Standby power | Generator | Dedicated generators | Per node, configured per site |
| Footprint | 36′ × 12′ vault | Two 36′ × 12′ buildings | Nine vaults on one fenced acre |
| Land requirement | — | — | 1.00 fenced acre · 1.3–1.6 acre parcel |
| Timeline | Months, not years | Months, not years | Months, not years |
Configurations shown are reference designs. Rack counts, rack density and IT platforms are specified per order. Lead times are factory scope, order to ship.
Supply-only or turnkey, scoped per site. Site preparation, permitting and utility power can affect the delivery schedule.
Speed, permanence and fit are usually a trade-off. Edge Vaults are built to give you all three.
Built and tested in our plants while your site is prepared. Fewer trades on site, fewer surprises. Months, not years.
Precast concrete designed to ASCE Risk Category IV wind loads (200 mph),* with a 30+ year design life.
Standard configurations from one 200 kW vault to multi-acre campuses, placed where the power is.
Add capacity in phases as demand is signed, on the same proven design each time.
You already run the sites. Add computing power at towers, huts and substations you operate, built by the team that builds your shelters.
See the EVU-200You need capacity you control, fast. Dedicated, single-tenant campuses on your land, from one node to many acres.
See the EVC-2500You have land near a substation, or power with room to spare. Tell us where it is.
Submit a siteYou have the customer and the opportunity. Bring it to us; we bring the building.
Become a partnerTell us what you need protected or powered. A dedicated sales manager stays with you from first call through completion, and you get a detailed quote on our factory scope, freight included.